Tech Brief #1043 - Prevent Stuck Ped Call (CCU2EN)
Polara’s technical bulletins are intended to provide updates, clarification, and guidance on the installation and maintenance of our products. They convey relevant technical product information to our partners and customers. Please contact us if you have any questions about the content of this bulletin.
Originally posted 3/18/2015.
Product / Models Affected:
CCU2EN, EZ Communicator Navigator (EN2)
Situation:
Some customers have reported a stuck ped call where the CCU2EN ped call light is on, indicating a self-test failure, but there are no flashing green ID LEDs
Solutions:
Investigation shows that this can only happen if an internal variable value gets altered unexpectedly to an invalid value. CIP firmware version 4.07 addresses this without regard to the actual cause. The variable is now screened continuously and corrected as needed.